Unlink profile from device

 

Description

This function is used to unlink a profile from a device. This will NOT remove the profile from the physical device. For that functionality, look at https://capasystems.atlassian.net/wiki/spaces/CI66DOC/pages/19610865474, which will do both.

Syntax

Public Function UnlinkUnitFromProfile(unitName As String, profileName As String, changelogComment As String) As Boolean

Parameters

UnitName(String)

The UnitName or UUID of the unit.

ProfileName(String)

The name of the MDM Profile

ChangelogComment (String)

A comment that will be added to the changelog entry on the profile and the device

Return value

Returns a boolean value. True if succeeded, otherwise false.

Example

VBScript
Set oCMS = CreateObject("CapaInstaller.SDK") Wscript.echo oCMS.SetDatabaseSettings("ServerName", "CapaInstaller", False) Wscript.echo oCMS.SetDefaultManagementPoint("2") Wscript.echo oCMS.UnlinkUnitFromProfile("Testdev01", "Wi-Fi settings", "Unlinked profile from device from SDK") Wscript.echo oCMS.UnlinkUnitFromProfile("4eea2959-fb4c-4afe-b61f-810cb3019cd6", "Wi-Fi settings", "Unlinked profile from device from SDK")