Symptom: After you have upgraded PerformanceGuard to a new version, the PerformanceGuard web interface looks strange (old icons, etc.) and/or you get error messages because the web interface can't connect to the PerformanceGuard Backend and Frontend servers.

Possible Causes & Solutions

This can happen if PerformanceGuard cache and work folders were not cleaned up before you started the new version of PerformanceGuard.
To clean up the folders:

  1. Select Image Removed Image Added /Start, type services.msc, press ENTER and stop the PerformanceGuard Backend Server, Frontend Server and Web Server services.
  2. Wiki Markup
    Go to \[PerformanceGuard installation folder\]\collector\cache\ and delete all files in that folder.
  3. Wiki Markup
    Go to \[PerformanceGuard installation folder\]\display\work\ and delete all files in that folder.
  4. Delete the log files in the following folders:
    1. Wiki Markup
      \[PerformanceGuard installation folder\]\collector\logs\
    2. Wiki Markup
      \[PerformanceGuard installation folder\]\display\logs\
    3. Wiki Markup
      \[PerformanceGuard installation folder\]\notification\work\
  5. Select Image Removed
  6. Image Added
  7.  /Start, type services.msc, press ENTER and start the PerformanceGuard Backend Server, Frontend Server and Web Server services again.