Add unit to reinstall

Description

Adds unit to reinstall.


Syntax

AddUnitToReinstall( Byval  ComputerName as String, Byval OSpointID as Integer, Byval OSserverID as Integer, Byval OSImageID as Integer, Byval  DiskConfigID as Integer, Byval  InstallTypeID as Integer, Optional Byval  NewUnitName as String = "", Optional Byval  ReinstallMode as String = "Silent", Optional Byval  Active as Boolean = True,  Optional Byval  UnlinkAllPackagesAndGroups as Boolean = False,  Optional Byval  UnlinkAllAdvPackages as Boolean = False,  Optional Byval  ChangelogComment as String = "") as Boolean


Parameters

ComputerName (String)

The name of the computer

OSpointID (Integer)

The OS Point ID

OSserverID (Integer)

The OS Server ID

OSImageID (Integer)

OS Image ID

DiskConfigID (Integer)

The Disk Configuration ID

InstallTypeID (Integer)

The Install Type ID

NewUnitName (String)

The new name of the unit. This parameter is optional, and if omitted, the unit will keep the existing name

ReinstallMode (String)

The reinstall can be initialized in three ways;

  • "Silent"
  • "AlwaysConfirm"
  • "ConfirmOnlyIfUserLoggedOn"
This parameter is optional. The default value is "Silent"

Active (Boolean)

Wether or not the computer should be active after the reinstall.

This parameter is optional. The default value is; True

UnlinkAllPackagesAndGroups (Boolean)

Wether or not all packages and groups should be unlinked

This parameter is optional. The default value is; False

UnlinkAllAdvPackages (Boolean)

Wether or not all advanced packages should be unlinked

This parameter is optional. The default value is; False

ChangelogComment (String)

The changelog comment for the change

This parameter is optional. The default value is; ""

ReinstallStartDate (String)

The reinstall start date in the format  "yyyy-MM-dd HH:mm" eg. "2015-04-15 12:05"

yyyy - Year with century.
MM - Numeric month with a leading zero.
dd - Numeric day of the month with a leading zero.
HH - 24 Hour clock with leading zero.
mm - Minutes with leading zero.

This parameter is optional. The default value is; "" which does not set a schedule for the reinstall but does it at next agent rerun.

Return Value

Boolean. The function returns True if successful, otherwise false.


Example

VBScript
Set oCMS = CreateObject("CapaInstaller.SDK") 
wscript.echo oCMS.SetDefaultManagementPoint("1") 
wscript.echo oCMS.AddUnitToReinstall("Klient","1","1","3","2","1","KlientNew","AlwaysConfirm",True,False,False,"comment") 

With Schedule

VBScript
Set oCMS = CreateObject("CapaInstaller.SDK") 
wscript.echo oCMS.SetDefaultManagementPoint("1") 
wscript.echo oCMS.AddUnitToReinstall("Klient","1","1","3","2","1","KlientNew","AlwaysConfirm",True,False,False,"comment","2015-05-05 12:00") 


or if the unit has to keep the same name: 

VBScript