Add unit to reinstall
Description
Adds unit to reinstall.
Syntax
AddUnitToReinstall( Byval  ComputerName as String, Byval OSpointID as Integer, Byval OSserverID as Integer, Byval OSImageID as Integer, Byval  DiskConfigID as Integer, Byval  InstallTypeID as Integer, Optional Byval  NewUnitName as String = "", Optional Byval  ReinstallMode as String = "Silent", Optional Byval  Active as Boolean = True, Optional Byval  UnlinkAllPackagesAndGroups as Boolean = False, Optional Byval  UnlinkAllAdvPackages as Boolean = False, Optional Byval  ChangelogComment as String = "") as Boolean
Parameters
ComputerName (String)
The name of the computer
OSpointID (Integer)
The OS Point ID
OSserverID (Integer)
The OS Server ID
OSImageID (Integer)
OS Image ID
DiskConfigID (Integer)
The Disk Configuration ID
InstallTypeID (Integer)
The Install Type ID
NewUnitName (String)
The new name of the unit. This parameter is optional, and if omitted, the unit will keep the existing name
ReinstallMode (String)
The reinstall can be initialized in three ways;
- "Silent"
- "AlwaysConfirm"
- "ConfirmOnlyIfUserLoggedOn"
Active (Boolean)
Wether or not the computer should be active after the reinstall.
This parameter is optional. The default value is; True
UnlinkAllPackagesAndGroups (Boolean)
Wether or not all packages and groups should be unlinked
This parameter is optional. The default value is; False
UnlinkAllAdvPackages (Boolean)
Wether or not all advanced packages should be unlinked
This parameter is optional. The default value is; False
ChangelogComment (String)
The changelog comment for the change
This parameter is optional. The default value is; ""
ReinstallStartDate (String)
The reinstall start date in the format  "yyyy-MM-dd HH:mm" eg. "2015-04-15 12:05"
yyyy - Year with century.
MM - Numeric month with a leading zero.
dd - Numeric day of the month with a leading zero.
HH - 24 Hour clock with leading zero.
mm - Minutes with leading zero.
This parameter is optional. The default value is; "" which does not set a schedule for the reinstall but does it at next agent rerun.
Return Value
Boolean. The function returns True if successful, otherwise false.
Example
Set oCMS = CreateObject("CapaInstaller.SDK") wscript.echo oCMS.SetDefaultManagementPoint("1") wscript.echo oCMS.AddUnitToReinstall("Klient","1","1","3","2","1","KlientNew","AlwaysConfirm",True,False,False,"comment")
With Schedule
Set oCMS = CreateObject("CapaInstaller.SDK") wscript.echo oCMS.SetDefaultManagementPoint("1") wscript.echo oCMS.AddUnitToReinstall("Klient","1","1","3","2","1","KlientNew","AlwaysConfirm",True,False,False,"comment","2015-05-05 12:00")
or if the unit has to keep the same name:Â
 wscript.echo oCMS.AddUnitToReinstall("Klient","1","1","3","2","1")